State verification of sample and working measuring means Radiation measurement in different environments Radiation monitoring and measuring procedures Accreditation of laboratories of radiation monitoring Examination of measuring instruments: verification, repair, maintenance and pattern approval LiteratureServices
- International cooperation
-
Unified solid phantom of whole body (UP-02T) Phantoms of lungs (PL-03T / PLP-05T phantoms) Phantom of thyroid (PT-04T phantom) Anatomic whole-body phantom (FTS-06T phantom) Characteristics of sources Whole body phantom ARDF-09TPhantoms
Production » Spectrometers and radiometers of radiation » Gamma and beta spectrometer - radiometer MKGB-01 RADEK
Gamma and beta spectrometer - radiometer MKGB-01 RADEK
The spectrometric complex consists of:
- Detection units BDEG-80, BDEG-63, BDEG-150, BDEG-K, BDEB-60 (on customer choice)
- Analog-to-digital converter (analyser) MD-198
- Controlled power supply of high voltage HV, power supply of low voltage LV
- Power supplies and gain units for BDEG-K
- Low-background chambers with shielding for units BDEG, BDEG-K and BDEB (on customer choice)
- Set of calibrating point sources of ionizing radiation (on customer request)
- Program for full spectrometric analysis "ASW"
- Personal computer IBM-PC of any configuration (on customer choice)
- Connecting cables
The following units can be included in the consist of spectrometric complex on separate order: - Printing complex (Automation system of counting samples accounting and marking) Shtrih-3
- Sample changer for beta and gamma tracts
Distinctive features
- Simultaneous and selective measurement of beta and gamma radiation
- Software in operating sistem Windows 98/ME/2000/XP/Vista/7
- Visualization of spectrum set process
- Conducting of computations during the spectrum set process
- Measurements automation
Spectrometer-radiometer MKGB-01 RADEK is registered in the State Register of Measuring Instruments of Russian Federation under № 21730-01. Pattern Approval Certificate of Measuring Instruments RU.C.38.001.A N 10702.
Main characteristics (in pdf):
|
Detection units of gamma-radiation |
|
|
- BDEG-80 |
80х80 |
|
- BDEG-63 |
63х63 |
|
- BDEG-150 |
150х100 |
|
- BDEG-K |
|
|
- - with sensitive surface area, mm2 |
no less than 100 |
|
- - with detection efficiency of gamma-radiation |
no less than 10 |
|
Detection units of beta-radiation |
|
|
- BDEB-60 |
60х12 |
|
Detectors power supplies |
|
- Controlled power supply of high voltage HV, |
|
- BNV-31 or its analogue for BDEG-K |
|
Analog-to-digital converter (analyser) MD-129, MD-198, MD-208 |
|
|
- with number of channels |
1024, 2048,4096,8192 |
|
- connection type to IBM PC |
LPT (MD-129), USB (MD-198), BlueTooth(MD-208) |
|
Range of registered energies, keV |
|
|
- of gamma-radiation |
50 - 3000 |
|
- of beta-radiation |
100 - 3000 |
|
Integral nonlinearity, % |
|
|
- for scintillation gamma-spectrometer |
no more than 1 |
|
- for scintillation beta-spectrometer |
no more than 2 |
|
- for semiconductor gamma-spectrometer |
no more than 0,05 |
|
Energy resolution |
|
|
- with detection unit BDEG-80 (BDEG-63) on gamma-line |
no more than 9 |
|
- with detection unit BDEG-150 on gamma-line |
no more than 13 |
|
- with detection unit BDEG-K on gamma-line 1332,5 keV of 60Со radionuclide, keV |
no more than 3,0 |
|
- with detection unit BDEB on conversion electrons peak with energy 624 keV of 137Cs radionuclide, % |
no more than 15 |
|
Maximum input statistical load, imp-1 |
no less than 50000 |
|
Continuous operation time, h |
24 |
|
Instability, |
no more than ±3 |
|
Operation mode setup time, min |
no more than 30 |
|
Measured radionuclides |
|
|
- with unit BDEG-K |
137Cs, 106Ru-106Rh, 134Cs, 144Ce-144Pr, 125Sb, 241Am, 226Ra, 232Th, 40K and etc. |
|
- with unit BDEG-80 (BDEG-63, BDEG-150) |
137Cs, 134Cs, 238U (226Ra), 232Th, 40K, 131I, 60Co |
|
- with unit BDEB |
90Sr-90Y, 137Cs |
|
Minimum detectable activity with measuring time 1 hour, Bq |
|
|
- 137Cs |
no more than 2 |
|
- 90Sr+90Y |
1 |
|
- 226Ra |
no more than 8 |
|
- 232Th |
no more than 5 |
|
- 40K |
no more than 40 |
|
- other gamma-radiating artificial radionuclides |
no more than n·1 - n·10 |
|
Limit of the main permissible error of measurements, % |
no more than ±30 |
|
Range of measurement of activities, Bq |
|
|
- 137Cs |
5 - 20·103 |
|
- 90Sr+90Y |
1 - 2·103 |
|
- 226Ra |
12 - 20·103 |
|
- 232Th |
8 - 8·103 |
|
- 40K |
50 - 20·103 |
|
- other gamma-radiating artificial radionuclides |
n·1 - n·106 |
|
Power, from the AC mains with frequency 50 Hz, V |
220 |
|
Power consumption, VA, no more than |
200 |
|
Range of operating temperatures, oC |
10 - 35 |
|
Weight, kg |
|
|
- of detection units BDEG and BDEB |
3,4 |
|
- of analog-to-digital converter MD-198 |
0,4 |
|
- of BDEG-K unit with Dewar flask and liquid nitrogen |
40 |
|
- of low-background chamber with passive shielding for BDEB unit |
80 |
|
- of low-background chamber with passive shielding for BDEG unit |
200 |
|
- of low-background chamber with passive shielding for BDEG-K unit |
200 |
|
- of spectrometer-radiometer MKGB-01 in assembly (with units BDEG-63/80/150) |
300 |
|
Overall dimensions of shielding units, mm |
|
|
- BDEG |
450х600 |
|
- BDEG-K with Dewar flask |
480х800 |
|
- BDEB |
300х400 |
|
Capacity of container for measuring materials, l |
|
|
- Marinelly container |
1 |
|
- Cylindrical container ("mayonez") |
0,25 |
|
- Cuvette |
0,038 |

Purchase equipment